Wedgelock for AT Plugs, 4-Way / AW4S
- Weight
- 0,001 kg
Herstellerdaten
Amphenol-Tuchel Industrial GmbH
Availability
Stock 1: Stück verfügbar
- Delivery time stock 1 when in stock: 1-3 days
Stock 2: Stück verfügbar
- Delivery time stock 2 when in stock: 5-7 working days
AT Series™
2, 3, 4, 6, 8 and 12 positions available- 14-20AWG, 13A, Size 16
- High-performance, cost-effective
- Superior environmental seal retention
- Compatible with existing standard products industry-wide
- RockSolid™ Contact technology (optional)
Overview
AT Series™ connectors are a high-performance, cost-effective solution able to be used in a variety of interconnect applications: Heavy Duty, Transportation, Marine, Diagnostic, Military, Alternative Energy and Agricultural. They contain superior environmental seals, seal retention capabilities and feature RockSolid™ Contact technology.
The connector design incorporates an integral latching system that ensures a definitive electrical and mechanical connection. Connector housings are manufactured with a thermoplastic material that is not only durable, but hasexcellent UV resistance, dielectric/mechanical properties and environmentally RoHS compliant. The sealing system is comprised of a front and rear silicone, multi-sealing perimeter against environmental ingress. Contacts are derived from quality copper alloy to ensure an electrically-reliable connection.
AT Series™ connectors are compatible with other existing standard products industry-wide.
Features & Benefits | |
---|---|
Current Capacity Size | 16, 13A (max) |
Wire Range | Size 16 contacts will accept wire ranges of 14 thru 20AWG |
Temperature | Operating temperature range: -55°C to +125°C at rated current |
Dielectric Value | Meets or exceeds 1500 volts minimum |
Drop Test | Shall not become detached or loosened when placed at 750mm and dropped to concrete eight times |
Shock | No latch disengagement or discontinuity shall be the result when subjected to 50 g’s in each of three axis (X, Y & Z) |
Vibration | Continued continuity without degradation to mechanical or physical attributes following vibration. (max acceleration 20 g’s at Sine sweep of 10-2000Hz) |
Connector Terminal Retention | When subjected to a direct pull, contacts achieve a minimum pull-out force of 25 lbs. |
Connector Retention | A mated connector subjected to a pulling force by the exiting wire bundle at 25 lbs. times the number of contacts to a maximum of 100 lbs. applying load for 30 seconds |
Thermal Shock | Subjected to 10 cycles at -55°C to +125°C with no cracking, chipping or other damage detrimental to the normal operation of the connector |
Insulation Resistance | 1000 megohms minimum at 25°C |
Mating Cycle Durability | Following 100 cycles of connection engagement and disengagement, degradation either mechanical or electrical is not evident |
Contact Millivolt Drop | Size 16 contacts with 16AWG conductor - 100 mV drop max at 13A test current |
Water Immersion | A mated connection, properly wired, placed in an oven at +125°C for 1 hour, then placed immediately in a depth of water of 1 meter for 4 hours without loss of electronic performance |
Product Material | |
Housings | Thermoplastic |
Seals | Silicone Elastomer |
Secondary Locks | Thermoplastic |
Contacts | Copper Alloy, Nickel Plated, Gold optional |
NOTE:
Wedgelocks are required for all plugs.